EL3102 PSU300M Control voltage: 24 V DC
Description
Control voltage: 24 V DC
EU standards: EN 61010-1:2010
For fixed point arithmetic
Interface: PROFIBUS DP with a maximum transmission rate of 12 Mbit/s and sender capability for direct data exchange
Distance between stations: 100 m (100BASE-TX)
EL3102 PSU300M Control voltage: 24 V DCNumber of inputs: 2 (differential) Voltage supply: via E bus Signal voltage: 10+10 V Distributed Clocks: yes Distributed Clocks accuracy: << 1 s Input resistance: > 200 k Input filter cutoff frequency: 5 kHz Common mode voltage UCM: max. 35 V (relative to internal GND) Conversion time: ~ 60 s (Fast Mode ~ 40 s) Resolution: 16 bit (including sign) Measurement error uncertainty: < 0. 3 % (relative to full scale value) Electrical isolation: 500 V (E bus